RC Beam Studio | ACI 318-19 Integrated Beam Design

Integrated reinforced concrete beam design studio per ACI 318-19. Unifies flexural capacity, one-way shear, torsion, immediate and long-term deflection, crack control, and rebar development into a continuous workflow with persistent cross-section and elevation drafting viewports.

Integrated reinforced concrete beam design studio per ACI 318-19. Unifies flexural capacity (φMn), one-way shear (φVn), torsion (φTn), immediate and long-term deflection, crack width control, and bar anchorage/detailing into an interactive engineering workspace.

Governing Code Standard: ACI 318-19 Chapters 9, 21, 22, 24, 25.

Calculations support dual units (SI metric and US Imperial). Outputs include demand-capacity ratios (DCR), step-by-step formula substitutions, parametric SVG technical drawings, and exportable calculation sheets. Free to use with no account or sign-up required.

Frequently Asked Questions

What checks are unified inside RC Beam Studio?

RC Beam Studio integrates positive and negative flexure (ACI 318-19 §22.2), one-way shear and stirrup zoning (§22.5), torsion (§22.7), immediate and long-term deflection (§24.2), crack control (§24.3), and bar development/hook anchorage (§25.4) on a single shared beam model.

What is the difference between Studio mode and Quick Check mode?

Studio mode evaluates your full beam model across all limit states with persistent 2D/3D drawings and multi-layer rebar. Quick Check provides a standalone single-check scratchpad and 1-page calculation audit sheet without altering your active studio beam.

Can RC Beam Studio receive loads from Continuous Beam analysis?

Yes. Using the Send To action bar in Continuous Beam, you can link governing positive moment, negative support moment, shear, and span length directly into RC Beam Studio with live provenance tracking.

Why does Flexure (-) show NOT EVALUATED on a simply supported beam?

A simply supported beam has no negative support moment, so the top-steel negative flexure check is not evaluated and the Mu (-) input is disabled. Switch the support condition to continuous or cantilever to evaluate it.

What does the What-If Rebar drawer do?

It compares alternative rebar layouts side by side with a bar-spacing clearance visualizer and a parameter sweeper, so you can test a different bar count or size and apply the variant to the studio beam in one click.

Which drawings and diagrams does RC Beam Studio include?

A 2D cross-section and elevation with stirrup zones, analysis diagrams for moment, shear, and deflection with an interactive scrubber, and a 3D rebar cage viewport. All views update live as you edit inputs.

Does RC Beam Studio support SI and Imperial units?

Yes. Switching between SI and Imperial loads sensible default inputs for the selected system, and the Reset button restores those defaults at any time.

Does RC Beam Studio replace the standalone beam calculators?

No. The standalone Beam Flexure, Beam Shear, Beam Torsion, Deflection Check, Crack Width, and Development Length calculators remain available. The studio runs the same checks together on one shared beam model.

RC Beam Studio
ACI 318-19 — Smart Defaults
Support Boundary Condition
Factored & Service Demands
Mu (+)
kN·m
Mu (-)auto?
kN·m

Zero at simple supports.

Vu Crit
kN
Tu
kN·m
Madead
kN·m
Malive
kN·m
Geometry & Materialsdagg = 19 mm
Width (b)
mm
Height (h)
mm
Cover
mm
Span (L)
mm
f'c
MPa
fy
MPa
fyt
MPa
dagg = 19 mm(Nominal maximum aggregate size defaulted to 19 mm / 0.75 in. per ACI 318-19 §25.2.1)
Rebar & Stirrups
Bot: 3ר25Top: 2ר16Stirrups: 2L-Ø10@200mm
Layout:
Cross Section
c = 81 mma = 68b = 300 mmh = 500 mm
Elevation & Stirrup Zones
L = 6.00 m2L-Ø10@200mm
Results
1. FlexurePASS
Mu(+) = 180 kN·m
φMn = 223.4 kN·m · DCR = 0.81
Open Flexure Details
2. Shear & TorsionPASS
Vu = 120 kN
φVn = 199.9 kN · DCR = 0.60
Open Shear Details
3. ServiceabilityPASS
Δtot = 19.9 mm ≤ Δlim = 16.7 mm
DCR = 0.34
Open Deflection Details
4. DetailingPASS
ld = 804 mm · ldh = 461 mm
Fit: OK
Open Detailing Details
Code ChecksPASS

This calculation is for preliminary design verification only. All results must be independently verified by a licensed professional engineer before use in construction documents.