Pile Cap Design Calculator | ACI 318-19

Design and verify rigid reinforced concrete pile caps supporting single or multiple columns. Analyzes 3D pile reaction distribution under combined axial loads and biaxial moments, checks one-way and punching shear at critical sections, and designs two-way orthogonal reinforcement grids.

Design and verify rigid reinforced concrete pile caps supporting single or multiple columns. Outputs: individual pile reactions, envelope demands, critical section beam shear, column and pile punching shear, flexural reinforcement, and parametric drafting visualization.

Governing Code Standard: ACI 318-19 §13.4, §22.5, §22.6.

Calculations support dual units (SI metric and US Imperial). Outputs include demand-capacity ratios (DCR), step-by-step formula substitutions, parametric SVG technical drawings, and exportable calculation sheets. Free to use with no account or sign-up required.

Frequently Asked Questions

How are individual pile reactions determined in a rigid pile cap?

Under the rigid cap assumption, pile reactions are calculated using the 3D flexure formula: Ri = P/N ± (Mx·yi)/Σy² ± (My·xi)/Σx², where N is the active pile count, (xi, yi) are pile coordinates relative to the group centroid, and Mx, My are moments transferred to the pile cap.

Where is the critical section for one-way (beam) shear in a pile cap per ACI 318-19?

Per ACI 318-19 §13.4.2, the critical section for beam shear is located at distance d from the column face. Any pile whose center lies beyond the critical section contributes its full factored reaction; piles intersected by the section contribute proportionally based on tributary pile area.

How is two-way punching shear evaluated in a pile cap?

Punching shear is evaluated at two distinct critical perimeters: (1) column punching at d/2 from the column perimeter, resisting total axial load minus pile reactions located within the perimeter, and (2) individual pile punching at d/2 from the pile perimeter per ACI 318-19 §22.6.

What is the minimum embedment depth and clear cover for pile caps?

Per ACI 318-19 §13.4.6 and §20.6.1.3, pile caps cast against soil require at least 75 mm (3 in) clear cover above the pile heads. Piles are typically embedded 50 mm to 100 mm (2 to 4 in) into the cap, requiring total cap thickness above rebar to be at least 300 mm (12 in).

When is strut-and-tie modeling (STM) required instead of sectional beam theory for pile caps?

Per ACI 318-19 §13.4.1.3, deep pile caps where the shear span-to-depth ratio a/d ≤ 2.0 behave as deep members (D-regions). In such cases, strut-and-tie modeling per Chapter 23 provides a more accurate representation of internal compressive struts and tensile ties than conventional sectional flexure.

Rigid 3D Pile Cap Design

3D Pile Cap Foundation

Rigid pile group with tension cutoff, biaxial moments & ACI 318-19 checks

+X+YPlan axes: Column b → cx (+X), Column h → cy (+Y)

Pile Group Layout & Capacities

Grid Rows (ny)
Grid Cols (nx)
Spacing sx
Spacing sy
Pile Coordinates (mm)
P1
P2
P3
P4
Pile Shape
Pile Diameter (dp)
Allowable Compression (Qall)
Allowable Uplift (Tall)

Cap Plan Bounds & Thickness

xmin
xmax
ymin
ymax
Cap Depth (h)
Concrete Cover
Bar Diameter (db)
Effective depth: d = h − cover − db = 805 mm (min 300 mm per §13.4.6.1)

Materials & Column Dimensions

f'c
fy
Column Width cx (b)
Column Depth cy (h)
Column Offset xc
Column Offset yc

Load Cases & Moment Senses

Row 1: Primary Case (Factored linkable from RC Column; Service manual)
Factored Axial Pu
Factored Moment Mux
Factored Moment Muy
Factored Vux
Factored Vuy
Row 1 Service Loads (Manual Geotechnical Input — P, Mx, My, Vx, Vy)
Service Axial P
Service Msx
Service Msy
Service Vsx
Service Vsy
Pile Cap Plan & Utilisation
PASS+X+Y525P1575P2625P3675P4R(38,75)Units: mm, kN | Green: Comp OK | Red: Tension/Overload | Grey (0): Cutoff
Results
1 flag ↓
deep cap (shear span av ≤ 2d): strut-and-tie check recommended per ACI 318-19 Chapter 23
Column Punching Shear · Case 1 (Primary) (+Mx, +My) · Factored · Pile P4Governing Limit State
0.61
PASS

Envelope Summary

Governing Case
Case 1 (Primary)
Governing Sense+Mx, +My
Governing RunFactored
Governing PileP4
Effective Depth d805 mm

Limit State Utilisation

Service Compression (Qall)
0.53PASS
Service Uplift (Tall)
0.00PASS
One-Way Shear (X & Y)
0.43PASS
Column Punching
0.61PASS
Pile Punching
0.40PASS
Flexure (X & Y)
0.58PASS

Governing Pile Reactions

Service & Factored
Pilex (mm)y (mm)R,serv (kN)R,fact (kN)State
P1-900-900373.6525Active
P2900-900406.9575Active
P3-900900443.1625Active
P4900900476.4675Active

Structural Reinforcement & Capacities

As,req (X)2694.9 mm²
As,min (X)4860 mm²
As,req (Y)2803.8 mm²
As,min (Y)4860 mm²

Engineering Assumptions

  • Rigid cap assumption (plane sections remain plane; linear reaction distribution with Ixy coupling).
  • Equal axial pile stiffness across all active piles in the group.
  • Linear elastic pile behavior up to tension cutoff (-Tall).
  • Pinned pile heads (zero rotational restraint at pile-to-cap interface).
  • Vertical piles only (no batter pile horizontal components).
  • Horizontal shear is included only as an overturning moment V*h about the pile heads; lateral pile and soil resistance are not checked.
  • No group efficiency reduction applied (Qall and Tall are user-supplied effective capacities).
  • Sectional design method: minimum effective depth d >= 300 mm per ACI 318-19 §13.4.6.1; pile reaction proration at critical sections per ACI 318-19 §13.4.6.5.
  • Deep-cap advisory: when shear span av <= 2d, strut-and-tie check per ACI 318-19 Chapter 23 is recommended while sectional results are still reported.
  • Cap and soil weight are included in the service run and excluded from the factored run.
Code CheckADVISORY

deep cap: strut-and-tie check recommended

This calculation is for preliminary design verification only. All results must be independently verified by a licensed professional engineer before use in construction documents.